Siemens S7 300 Programming Software

Posted By admin On 15/04/19

STEP 7 Lite is the easy to use and intuitive programming software for the implementation of stand-alone solutions with SIMATIC S7-300, SIMATIC C7, ET 200S (IM 151/CPU and IM 151/CPU FO) and ET 200X (BM 147/CPU). Watch jungle book 2016 online free full movie.

Siemens

Siemens S7 Software Free Download

plc controllers COMMUNICATION MODULE CM 1243-5 FOR CONNECTION OF SIMATIC S7-1200 TO PROFIBUS AS DP MASTER MODULE; PG/OP COMMUNICATION; S7-COMMUNICATION

Transmission rate
Transmission rate / at interface 1 / in accordance with PROFIBUS9.6 kbit/s…12 Mbit/s
Interfaces
Number of electrical connections
  • at interface 1 / in accordance with PROFIBUS
1
  • for power supply
1
Design of electrical connection
  • at interface 1 / in accordance with PROFIBUS
9-pin Sub-D socket (RS485)
Supply voltage, current consumption, power loss
Type of voltage / of supply voltageDC
Supply voltage
  • external
24 V
Relative positive tolerance / at 24 V / with DC20 %
Relative negative tolerance / at 24 V / with DC20 %
Consumed current
  • from external supply voltage / at 24 V / with DC
  • typical
0.1 A
Resistive loss2.4 W
Permitted ambient conditions
Ambient temperature
  • for vertical installation / during operating phase
0…45 °C
  • for horizontal installation / during operating phase
0…55 °C
  • during storage
-40…+70 °C
  • during transport
-40…+70 °C
Relative humidity / at 25 °C / without condensation / during operating / maximum95 %
Protection class IPIP20
Design, dimensions and weight
Width30 mm
Height100 mm
Depth75 mm
Net weight0.134 kg
Product properties, functions, components / general
Number of modules
  • per CPU / maximum
1
Performance data
Performance data / PROFIBUS DP
Service / as DP master / DPV1Yes
Number of DP slaves / on DP master / usable16
Amount of data
  • of the address area of the inputs / as DP master / overall
512 byte
  • of the address area of the outputs / as DP master / overall
512 byte
  • of the address area of the inputs / per DP slave
244 byte
  • of the address area of the outputs / per DP slave
244 byte
  • of the address area of the diagnostic data / per DP slave
240 byte
Service / as DP slave
  • DPV0
No
  • DPV1
No
Performance data / S7 communication
Number of possible connections / for S7 communication
  • maximum
8
  • with PG connections / maximum
1
  • with PG/OP connections / maximum
3
  • note
max. 4 connections to other S7 stations
Performance data / multi-protocol mode
Number of active connections / with multi-protocol mode
  • without DP / maximum
8
  • with DP / maximum
8